Nikon Eclipse MA100 Inverted Materials Metallograph
The MA100 is a new compact inverted microscope designed for the routine observation and analysis of prepped material and metallurgical samples in the automotive, aerospace, medical device and electronics industry. The small size footprint makes it an affordable instrument with outstanding optical performance, ideal for in-line sample inspection for the manufacturing, production and assembly environments that require quality control of materials.
Features:
Powerful NIS-Elements Imaging Software
Nikon’s NIS-Elements Documentation imaging software package allows users to perform everything from basic image capture to the measurement, analysis, and management of captured images. Users can add a wide array of the plug-ins to basic packages according to their intended use.
Durable Stage
Nikon developed the all-new MA-SR Rectangular Stage especially for the MA100. The three-plate structure gives the microscope stable control and superior durability and enables observation of heavy samples, including embedded samples that are still mounted on a grinder’s holder.
CFI60 Optical System
Nikon’s proprietary CFI60 optics provide high NA and a longer working distance. CFI60 optics deliver bright, high-resolution images. Up to five objective lenses can be mounted.
Aperture Diaphragm
The epi illuminator comes standard with a condenser which enables users to control image contrast and depth of field of the sample.
Adjustable Mirror
The Eclipse MA100 ships complete with a mirror for checking objective lenses, which makes observation much more efficient. Now users can verify what objective lens is being used as well as the observation position of the sample in a comfortable position, without having to look beneath the stage.
Polarizer/Analyzer
This device makes possible simple polarizing observation, which is effective for samples such as polymer materials. It takes just a single action to engage the polarizer and analyzer in the light path. The polarizer can rotate 360°, allowing users to set a polarization direction suited to the sample being observed.
Integration with Digital Sight Camera System
Nikon Digital Sight cameras are versatile, high-resolution digital systems that enable various configurations consisting of a camera head and a control unit to suit the needs of each sample or application.
DS-Fi1 High Definition Color Camera Head - features a 5-megapixel CCD that faithfully captures 2,560 x 1,920-pixel high-resolution images. This camera head features frame rates far beyond conventional models with improved image quality and ease of use, including a refined IR cut filter. Advanced functionality and high cost performance are the hallmarks of the DS-Fi1.
DS-2Mv High Speed Color Camera Head - features a 2-megapixel CCD that displays SXGA video at a high frame rate of 15 fps (max. 30fps). This camera head enables the smooth display of live images and the capture of crystal-clear still images with a high sensitivity. With the exceptionally high frame rates it can even be used for live monitoring.
DS-U2 PC Based-Control Unit - Offering simple connection via high speed USB 2.0, the DS-U2 controls everything from live image display and capture to advanced image processing and analysis on a computer. It supports a wide range of applications.
DS-L2 Stand-alone Control Unit - The DS-L2 features a large high-definition LCD and a host of features. There is no need for a PC and monitor, which allows the system to be used with a flick of a switch.
Powerful NIS-Elements Imaging Software
Nikon's NIS-Elements Documentation imaging software package allows users to perform everything from basic image capture to the measurement, analysis, and management of captured images. Users can add a wide array of the plug-ins to basic packages according to their intended use.
Durable Stage
Nikon developed the all-new MA-SR Rectangular Stage especially for the MA100. The three-plate structure gives the microscope stable control and superior durability and enables observation of heavy samples, including embedded samples that are still mounted on a grinder's holder.
CFI60 Optical System
Nikon's proprietary CFI60 optics provide high NA and a longer working distance. CFI60 optics deliver bright, high-resolution images. Up to five objective lenses can be mounted.
Aperture Diaphragm
The epi illuminator comes standard with a condenser which enables users to control image contrast and depth of field of the sample.
Adjustable Mirror
The Eclipse MA100 ships complete with a mirror for checking objective lenses, which makes observation much more efficient. Now users can verify what objective lens is being used as well as the observation position of the sample in a comfortable position, without having to look beneath the stage.
Polarizer/Analyzer
This device makes possible simple polarizing observation, which is effective for samples such as polymer materials. It takes just a single action to engage the polarizer and analyzer in the light path. The polarizer can rotate 360°, allowing users to set a polarization direction suited to the sample being observed.
Integration with Digital Sight Camera System
Nikon Digital Sight cameras are versatile, high-resolution digital systems that enable various configurations consisting of a camera head and a control unit to suit the needs of each sample or application.
DS-Fi1 High Definition Color Camera Head
Features a 5-megapixel CCD that faithfully captures 2,560 x 1,920-pixel high-resolution images. This camera head features frame rates far beyond conventional models with improved image quality and ease of use, including a refined IR cut filter. Advanced functionality and high cost performance are the hallmarks of the DS-Fi1.
DS-2Mv High Speed Color Camera Head
Features a 2-megapixel CCD that displays SXGA video at a high frame rate of 15 fps (max. 30fps). This camera head enables the smooth display of live images and the capture of crystal-clear still images with a high sensitivity. With the exceptionally high frame rates it can even be used for live monitoring.
DS-U2 PC Based-Control Unit
Offering simple connection via high speed USB 2.0, the DS-U2 controls everything from live image display and capture to advanced image processing and analysis on a computer. It supports a wide range of applications.
DS-L2 Stand-alone Control Unit
The DS-L2 features a large high-definition LCD and a host of features. There is no need for a PC and monitor, which allows the system to be used with a flick of a switch.
- Optics:
- CFI60 optics
- Observation method:
- Brightfield and simple polarizing (when using MA-P/A Simple Polarizing Set)
- Focusing section:
- Vertical action revolver (fixed stage) Single-axis coarse/fine adjustment handle with 8.5mm stroke (coarse adjustment of 37.7mm per turn, fine adjustment of 0.2mm per turn)
- Nosepiece:
- Brightfield 5-position nosepiece
- Stage:
- MA-SP Plain Stage: 170 x 230mm (includes two holders for acrylic samples φ30mm aperture, crescent aperture) Can be combined with MA-SRSH1 Universal Specimen Holder or MA-SH3 Specimen Holder 3.
- TI-SM Mechanical Stage CH: 126 x 80mm stroke; Handle can be attached on the right or left side of the stage Can be combined with MA-SH1 Specimen Holder 1, MA-SH2 Specimen Holder 2, or C-HU Universal Holder.
- MA-SR Rectangular Stage: 50 x 50mm stroke (includes two sample holders at φ20mm and 40mm apertures) and handle fixed on right side. Can be combined with MA-SRSH1 Universal Specimen Holder or MA-SH3 Specimen Holder 3.
- Illuminator:
- Internal power supply 6V 30W Halogen Lamp (long-life type) Condenser built-in (lever operated)φ25mm filter (includes NCB11 and ND4) can be inserted.
- Eyepiece tube:
- Built-in mirror type, 45°depression angle and 50 to 75mm interpupillary adjustment Max. power consumption: 96VA
- External dimensions:
- Width: 228mm
- Depth: 663mm
- Height: 382mm
- Weight:
- Approx. 9kg
This area is currently undergoing maintenance, please check back often for updates. For any questions, additional information or to place an order,
please call 1-860-741-3435 or contact us, thank you.